Skip to content
Fan and Frost

The picks

The best mini splits for a cold climate, ranked on what they still deliver at five degrees

Every mini-split brochure says cold climate. The certified dataset says so too — about 85 percent of the time — which makes the label useless as a filter and leaves two figures doing all the work.

By Sawyer V. · Published

The short answer

On certified figures the Fujitsu AOUH09KTAP1 wins outright: 17,000 BTU of heat at 5 F from a 9,000 BTU unit, at a COP of 2.48. It is sold through contractors. The best you can buy as a complete kit is the Senville AURA SENA-12HF — 11,500 BTU at 5 F, COP 1.80, and SEER2 25.4.

Fan & Frost earns a commission when you buy through our links, at no cost to you. It never changes a ranking, and we say so when the right answer is the cheaper unit or nothing at all. Full disclosure · How we pick.

A car parked in a snowy driveway beside a white house

At a glance

The picks, ranked

Tap any row to jump to the full reasoning. Prices are live from Amazon where we have them, and read “check price” where we don’t — never a number we cannot verify today.

#ProductBest forPrice
1

Best certified performance in the cold

Fujitsu Mini-Split Heat Pump, 9,000 BTU

17,000 BTU of certified heating capacity at 5 F from a 9,000 BTU unit, at a coefficient of performance of 2.48 — the highest 5-degree COP of any 9,000 BTU unit we compared. SEER2 33.5 and HSPF2 14.00 as well.

A room or a small dwelling in a genuinely cold place, where the heat pump is expected to be the heating rather than a shoulder-season convenience — and where a contractor is doing the install anyway

Not sold on Amazon. Fujitsu sells through its own dealers.

2
Senville SENA-12HF (certified as SENA-12HF-OG)

Best you can buy as a kit

Senville AURA Mini-Split Heat Pump, 12,000 BTU

11,500 BTU of certified heat at 5 F from a 12,000 BTU unit at a COP of 1.80, with SEER2 25.4, a published minimum heating temperature of −22 F, and a 10-year compressor warranty.

A room addition, a garage conversion or a cabin where you want the whole system in one box with a line set, and are willing to accept a lower cold-weather coefficient for a published price
$1,399.99 · View on Amazon

Price as of November 15, 2026

#ad How we earn

3

Best balance of efficiency and cold output

Mitsubishi Electric Mini-Split Heat Pump, 9,000 BTU

14,700 BTU of certified heat at 5 F from a 9,000 BTU unit, COP 2.20, SEER2 33.1 and HSPF2 13.30. Second only to the Fujitsu on 5-degree performance, and ahead of everything buyable.

A cold-climate retrofit where the install will be done properly and the owner intends to keep the house — the brand with the deepest cold-climate record and figures to match

Not sold on Amazon. Mitsubishi Electric sells through its own dealers.

4

Highest cold COP of any size

Carrier Mini-Split Heat Pump, 18,000 BTU

A COP of 2.89 at 5 F, the highest figure in this comparison at any capacity, with 24,000 BTU of certified heat at 5 F from an 18,000 BTU unit.

A larger space — an open-plan addition, a converted barn, a dwelling rather than a room — where 18,000 BTU is the right size and the 5-degree coefficient is the thing being bought

Not sold on Amazon. Carrier sells through its own dealers.

5
Senville SENA-18HF (certified as SENA-18HF-OG)

Best large unit you can buy as a kit

Senville AURA Mini-Split Heat Pump, 18,000 BTU

18,000 BTU of certified heat at 5 F from an 18,000 BTU unit — 100 percent capacity retention — at a COP of 1.92, with the same −22 F minimum and 10-year compressor warranty as its smaller sibling.

A larger space you are fitting out yourself or with a local installer, where the 18,000 BTU capacity and a published price together beat a better coefficient you cannot buy
$1,599.99 · View on Amazon

Price as of November 15, 2026

#ad How we earn

—
Senville SENL-12CD

The one to skip

Senville LETO Mini-Split Heat Pump, 12,000 BTU

Senville's cheaper line, at SEER2 21.2 and a published minimum heating temperature of −15 C, which Senville's own FAQ puts at 5 F. There is no ENERGY STAR record for it at all.

A mild climate on a tight budget — which is a legitimate purchase and is not what this page is about
$799.99 · View on Amazon

Price as of November 15, 2026

#ad How we earn

“Cold climate” is the phrase on every mini-split brochure in the northern half of the country, and it is also a formal ENERGY STAR designation with a field in the public dataset. So the obvious way to shop is to filter on it.

That does not work, and here is why.

The finding

85 percent of certified mini splits carry the cold-climate label

The ENERGY STAR Certified Mini-Split Heat Pumps dataset holds 18,036 records. We queried the cold-climate field across all of them:

15,319 of 18,036 records — 85 percent — are marked cold climate: Yes, across 223 different outdoor-unit brands.

A filter that keeps five of every six candidates is not a filter. It tells you a unit is not the very worst thing on the market, and that is all it tells you.

What the same dataset also publishes, per record, is far more useful: heating capacity at 47 F, at 17 F and at 5 F, plus a coefficient of performance at 5 F. Those two 5-degree columns are the real cold-climate specification, and almost nobody shops on them.

The two figures

Capacity at five degrees, and COP at five degrees

UnitRated coolHeat at 17 FHeat at 5 F% of ratedCOP at 5 FSEER2
Fujitsu AOUH09KTAP19,0007,40017,000189%2.4833.5
Mitsubishi MUZ-FX09NLHZ9,0007,70014,700163%2.2033.1
Hisense AO-09U3T25P9,00013,00012,200136%2.2532.0
Senville SENA-12HF12,00012,00011,50096%1.8025.4
Carrier 38MPRBQ18AA318,00020,20024,000133%2.8926.3
Senville SENA-18HF18,00018,00018,000100%1.9221.4
Senville SENL-12CD12,000Not certifiedNot certified—Not certified21.2

All BTU/h and COP figures from the ENERGY STAR Certified Mini-Split Heat Pumps dataset. The “% of rated” column is our arithmetic: 5-degree heating capacity divided by rated cooling capacity. Every certified unit here is marked cold climate: Yes, which is exactly the problem.

Read the COP column and the whole page is decided in one glance. Across the small single-zone units — the 9,000 and 12,000 BTU rows — the certified coefficient at five degrees runs from 1.80 to 2.48, which means one of them needs 38 percent more electricity than another to put the same heat in the same room on the same January morning. Every one of them carries the same cold-climate label.

Two honest caveats about that table, because it looks stranger than it is. First, several units publish more capacity at 5 F than at 17 F. Those are different test points submitted under different conditions rather than one smooth curve, so read each column against its own peers rather than across the row. Second, the dataset publishes no sound figure at all — not for any of 18,036 records — so the only acoustic numbers on this page are Senville’s own.

Why it matters

Capacity at five degrees is a sizing question, not a bragging one

A mini split is usually sized on the cooling load, because that is the number the installer has in front of them. In a cold climate that is the wrong way round: the heating load is the bigger of the two, and it peaks on the coldest night rather than the hottest afternoon.

So the useful question is not “how many BTU is it?” but “how many BTU does it still make when it is 5 F outside?” Three of the units above answer that with more than their rated capacity. One answers it with exactly its rated capacity. One has no answer at all.

And the COP answers the second question, which is what that heat costs. A COP of 2.48 means 2.48 units of heat per unit of electricity — against 1.0, exactly and permanently, for any electric resistance heater. Which is what a wall unit with heat gives you below 45 F.

This one is not a DIY job

A cold-climate heat pump with a bad install is a bad heat pump. Every figure on this page assumes a correctly charged line set, a properly sized unit and an outdoor unit mounted clear of the snow line with room to drain its defrost cycle. None of those is a product choice. If you are weighing a DIY kit against a contractor install, weigh that too. What a mini split actually costs installed, and what it costs per month afterwards.

The refrigerant

R-454B, R-32 and R-410A are not interchangeable choices

Five of the seven units here use the newer low-GWP refrigerants and one does not, and over a fifteen-year service life that is worth a paragraph.

  • R-454B, GWP 470 — Senville AURA, Mitsubishi, Hisense.
  • R-32, GWP 675 — Fujitsu.
  • R-410A, GWP 2,088 — Carrier/Bryant.

That is a factor of four and a half between the best and worst on this page, on a charge that will eventually leak or be recovered. What the refrigerant change means for buyers.

Say the unwelcome thing

Do not buy on the cold-climate badge.

Fifteen thousand three hundred and nineteen certified records carry it. It is on the cheapest unit in the dataset and the most expensive one, on the unit with a 5-degree COP of 1.8 and the one at 2.89.

Ask for two numbers instead, and ask for them in writing: the heating capacity at 5 F and the COP at 5 F, for the exact outdoor model number being quoted. Both are published, free, and searchable in the federal dataset by anyone with the model number.

In full

Every pick, and what is wrong with it

Published specifications only, each linked to the page it came from. Where a manufacturer publishes nothing, the row says so — we do not fill blanks in.

1. Best certified performance in the cold

Fujitsu Mini-Split Heat Pump, 9,000 BTU

Fujitsu · model AOUH09KTAP1

17,000 BTU of certified heating capacity at 5 F from a 9,000 BTU unit, at a coefficient of performance of 2.48 — the highest 5-degree COP of any 9,000 BTU unit we compared. SEER2 33.5 and HSPF2 14.00 as well.

Certified heating: 12,000 BTU at 47 F, 7,400 at 17 F and 17,000 at 5 F, with a COP at 5 F of 2.48. Read that last pair twice. At five degrees Fahrenheit this unit is certified to deliver 189 percent of its rated cooling capacity in heat, while still returning nearly two and a half units of heat per unit of electricity.

SEER2 33.5, EER2 19.1, HSPF2 14.00, R-32 refrigerant, ENERGY STAR certified and on the Most Efficient list. It is the most efficient machine in any category this site covers, in both directions.

It also has no price on this page, and that is a real cost. Fujitsu’s channel is contractors; there is no listing to buy and no number to compare. If you are getting quotes anyway, ask for this model by number — the specification is the argument.

One gap worth stating: the certified dataset publishes no sound figure for any mini split, Fujitsu included. For an outdoor unit under a bedroom window that matters, and it is unavailable for the whole category. How the mini-split brands compare across the dataset.

What’s wrong with it

There is no buy link. Fujitsu sells through contractors, there is no AOUH09KTAP1 listing on Amazon, and the Fujitsu wall-mounted product path returned 404 from this build — so you cannot price it yourself, and the certified dataset publishes no sound figure for it either.

Running cost

Fujitsu does not publish a wattage for the AOUH09KTAP1, so we cannot calculate what it costs to run. We are not going to estimate one. If Fujitsu publishes a nameplate figure, this block will show the arithmetic.

Published specifications
Cooling capacity9,000 BTU/h
SEER233.5
EER219.1
HSPF214.00
COP at 5 degrees F2.48
Cold climateYes
RefrigerantR-32 (GWP 675)
ENERGY STARCertified, and on the Most Efficient list
NoiseNot published in the certified dataset

Every figure above is from ENERGY STAR Certified Mini-Split Heat Pumps dataset. Blanks are shown as “not published” rather than filled in.

Amazon does not carry this model. Fujitsu sells it through its own dealers, and we have no affiliate relationship there — so there is no buy button here rather than one that earns us nothing. The figures above are the manufacturer’s published or certified ones, and the source is cited below them.

Senville SENA-12HF (certified as SENA-12HF-OG)

2. Best you can buy as a kit

Senville AURA Mini-Split Heat Pump, 12,000 BTU

Senville · model SENA-12HF (certified as SENA-12HF-OG)

11,500 BTU of certified heat at 5 F from a 12,000 BTU unit at a COP of 1.80, with SEER2 25.4, a published minimum heating temperature of −22 F, and a 10-year compressor warranty.

Certified: 12,000 BTU at 47 F, 12,000 at 17 F, 11,500 at 5 F, COP at 5 F of 1.80, SEER2 25.40, EER2 13.40, HSPF2 10.50, R-454B, ENERGY STAR Most Efficient.

Senville publishes a minimum heating temperature of −22 F (−30 C), plus indoor sound at 47 / 40 / 34 / 24 dB across turbo, high, medium and low and 57 dB outdoors. That makes it the only unit on this page with any published acoustic figure at all, because the federal dataset has none.

The model-number chain is worth explaining, because this site cares about it. The listing says only “Senville AURA, 12000 BTU”. Senville’s own AURA 12,000 BTU page publishes SEER2 25.4 and EER2 13.4 for model SENA/12HF — which matches the certified SENA-12HF-OG record exactly. The figures close the loop even though the box does not.

10 years on the compressor, 5 years on parts, which is the longest warranty on this page and a real part of the proposition at this price. Whether a mini split pays back.

What’s wrong with it

A COP of 1.80 at 5 F is the lowest of the units compared here — it does the job in the cold but costs about a third more per unit of heat than the Fujitsu. It is also the only unit on this page that holds LESS than its rated capacity at 5 F, at 96 per cent. The retail listing prints no model number, so the chain to the certified record runs through Senville's own published efficiency figures rather than a part number on the box.

Running cost

Senville does not publish a wattage for the SENA-12HF (certified as SENA-12HF-OG), so we cannot calculate what it costs to run. We are not going to estimate one. If Senville publishes a nameplate figure, this block will show the arithmetic.

Published specifications
Cooling capacity12,000 BTU/h
Heating capacity at 47 F12,000 BTU/h
Heating capacity at 17 F12,000 BTU/h
Heating capacity at 5 F11,500 BTU/h — 96% of its rated cooling capacity
COP at 5 F1.80
SEER225.4
EER213.4
HSPF210.50
Minimum heating temperature-22 F (-30 C), per Senville
Cold climateYes
ENERGY STARCertified, and on the Most Efficient list
RefrigerantR-454B
Power208/230 V, 1 phase, 60 Hz (187 - 253 V)
Indoor noise47 / 40 / 34 / 24 dB turbo / high / medium / low
Outdoor noise57 dB
Warranty10 years compressor, 5 years parts

Every figure above is from ENERGY STAR Certified Mini-Split Heat Pumps dataset. Blanks are shown as “not published” rather than filled in.

$1,399.99 · View on Amazon

Price as of November 15, 2026

#ad How we earn

3. Best balance of efficiency and cold output

Mitsubishi Electric Mini-Split Heat Pump, 9,000 BTU

Mitsubishi Electric · model MUZ-FX09NLHZ

14,700 BTU of certified heat at 5 F from a 9,000 BTU unit, COP 2.20, SEER2 33.1 and HSPF2 13.30. Second only to the Fujitsu on 5-degree performance, and ahead of everything buyable.

12,000 BTU at 47 F, 7,700 at 17 F, 14,700 at 5 F, COP 2.20 at 5 F, SEER2 33.10, EER2 18.35, HSPF2 13.30, R-454B. That is 163 percent of rated capacity as heat at five degrees.

Mitsubishi Electric has 463 cold-climate certified records — more than any manufacturer except the private-label specialists — which is a different kind of evidence from a single good model. The engineering is deep in this condition rather than present in one SKU.

A dataset note for anyone verifying this themselves, because it cost us time once: the certified record is stored as MUZ-FX09NLHZ*** with trailing asterisks for variants, so an exact-match query returns nothing. Search on a partial match.

Like the Fujitsu, it is sold through dealers, which is why the buy link goes to Mitsubishi’s own site rather than a retailer. What a mini split costs to run, computed from these figures.

What’s wrong with it

Also contractor-only, with no Amazon listing, so there is no price here either. The dataset stores it as MUZ-FX09NLHZ*** with variant asterisks, which means an exact model-number lookup fails unless you search on a partial match — a trap we have hit before on this site.

Running cost

Mitsubishi Electric does not publish a wattage for the MUZ-FX09NLHZ, so we cannot calculate what it costs to run. We are not going to estimate one. If Mitsubishi Electric publishes a nameplate figure, this block will show the arithmetic.

Published specifications
Cooling capacity9,000 BTU/h
SEER233.1
EER218.35
HSPF213.30
COP at 5 degrees F2.20
Cold climateYes
RefrigerantR-454B (GWP 470)
ENERGY STARCertified, and on the Most Efficient list
NoiseNot published in the certified dataset

Every figure above is from ENERGY STAR Certified Mini-Split Heat Pumps dataset. Blanks are shown as “not published” rather than filled in.

Amazon does not carry this model. Mitsubishi Electric sells it through its own dealers, and we have no affiliate relationship there — so there is no buy button here rather than one that earns us nothing. The figures above are the manufacturer’s published or certified ones, and the source is cited below them.

4. Highest cold COP of any size

Carrier Mini-Split Heat Pump, 18,000 BTU

Carrier · model 38MPRBQ18AA3

A COP of 2.89 at 5 F, the highest figure in this comparison at any capacity, with 24,000 BTU of certified heat at 5 F from an 18,000 BTU unit.

20,000 BTU at 47 F, 20,200 at 17 F, 24,000 at 5 F, COP at 5 F of 2.89, SEER2 26.30, EER2 15.30, HSPF2 11.00. Nothing else in this comparison reaches 2.89 in the cold.

At 18,000 BTU it is the only large unit here, and sizing matters more in heating than in cooling: a unit sized for a room’s cooling load in July is frequently undersized for its heating load in January, which is where the 5-degree capacity figure earns its keep. Sizing, and why the two loads differ.

The refrigerant is the mark against it. R-410A has a published global warming potential of 2,088 against 675 for R-32 and 470 for R-454B. On a machine that may be in a wall for fifteen years, that is not a footnote. R-32 against R-410A.

A naming note: the dataset lists this model number under Bryant, which is the same corporate engineering sold under a second brand. The certified figures are identical.

What’s wrong with it

R-410A refrigerant at a global warming potential of 2,088, against R-32 at 675 and R-454B at 470 — a real difference in a product with a decades-long life. Dealer-only, so there is no price. The same model number appears in the dataset under the Bryant brand, which shares Carrier's engineering.

Running cost

Carrier does not publish a wattage for the 38MPRBQ18AA3, so we cannot calculate what it costs to run. We are not going to estimate one. If Carrier publishes a nameplate figure, this block will show the arithmetic.

Published specifications
Cooling capacity18,000 BTU/h
SEER226.3
EER215.3
HSPF211.00
COP at 5 degrees F2.89
Cold climateYes
RefrigerantR-410A (GWP 2,088)
ENERGY STARCertified, and on the Most Efficient list
NoiseNot published in the certified dataset

Every figure above is from ENERGY STAR Certified Mini-Split Heat Pumps dataset. Blanks are shown as “not published” rather than filled in.

Amazon does not carry this model. Carrier sells it through its own dealers, and we have no affiliate relationship there — so there is no buy button here rather than one that earns us nothing. The figures above are the manufacturer’s published or certified ones, and the source is cited below them.

Senville SENA-18HF (certified as SENA-18HF-OG)

5. Best large unit you can buy as a kit

Senville AURA Mini-Split Heat Pump, 18,000 BTU

Senville · model SENA-18HF (certified as SENA-18HF-OG)

18,000 BTU of certified heat at 5 F from an 18,000 BTU unit — 100 percent capacity retention — at a COP of 1.92, with the same −22 F minimum and 10-year compressor warranty as its smaller sibling.

Certified: 18,000 BTU at 47 F, 18,000 at 17 F, 18,000 at 5 F, COP 1.92 at 5 F, SEER2 21.40, EER2 12.50, HSPF2 11.00, R-454B, ENERGY STAR Most Efficient.

Flat capacity across all three test points is itself informative. Several units here are certified to deliver more heat at 5 F than at 17 F; this one holds exactly its rated figure at every temperature. For sizing that is the easiest kind of unit to reason about: what it says is what you get, warm or cold.

Senville publishes −22 F as the minimum heating temperature, 49 / 43.5 / 38.5 / 27 dB indoors and 59 dB outdoors, with the same 10-year compressor and 5-year parts warranty.

The efficiency drop against the 12,000 BTU AURA is real — SEER2 21.4 against 25.4 — and that is normal across this dataset: bigger units in a family are usually less efficient. Oversizing therefore costs twice.

What’s wrong with it

SEER2 21.4 against the smaller AURA's 25.4, so it is less efficient in cooling, and a COP of 1.92 in the cold is well behind the Carrier's 2.89 at the same capacity. Its 49 dB indoor high-speed figure is also the loudest Senville publishes for the line.

Running cost

Senville does not publish a wattage for the SENA-18HF (certified as SENA-18HF-OG), so we cannot calculate what it costs to run. We are not going to estimate one. If Senville publishes a nameplate figure, this block will show the arithmetic.

Published specifications
Cooling capacity18,000 BTU/h
Heating capacity at 47 F18,000 BTU/h
Heating capacity at 17 F18,000 BTU/h
Heating capacity at 5 F18,000 BTU/h — 100% of its rated cooling capacity
COP at 5 F1.92
SEER221.4
EER212.5
HSPF211.00
Minimum heating temperature-22 F (-30 C), per Senville
Cold climateYes
ENERGY STARCertified, and on the Most Efficient list
RefrigerantR-454B
Power208/230 V, 1 phase, 60 Hz (187 - 253 V)
Indoor noise49 / 43.5 / 38.5 / 27 dB turbo / high / medium / low
Outdoor noise59 dB
Warranty10 years compressor, 5 years parts

Every figure above is from ENERGY STAR Certified Mini-Split Heat Pumps dataset. Blanks are shown as “not published” rather than filled in.

$1,599.99 · View on Amazon

Price as of November 15, 2026

#ad How we earn

Senville SENL-12CD

Skip this one

Senville LETO Mini-Split Heat Pump, 12,000 BTU

Senville · model SENL-12CD

Senville's cheaper line, at SEER2 21.2 and a published minimum heating temperature of −15 C, which Senville's own FAQ puts at 5 F. There is no ENERGY STAR record for it at all.

The LETO is a perfectly reasonable mini split and it is the wrong one for this page, for a reason that is easy to state.

Senville publishes a minimum heating temperature of −15 C for the SENL-12CD, and its own FAQ gives that as 5 F. Five degrees Fahrenheit is the test point at which every certified unit above is rated. This one is at its published floor there.

And there is no certified record to look it up in. We searched the ENERGY STAR mini-split dataset for SENL-12CD and found nothing, and Senville does not claim ENERGY STAR on the page for this model. So there is no 5-degree capacity, no COP at 5 F and no Most Efficient status.

What it does publish is SEER2 21.2, EER2 10.1, HSPF2 8.7 in region 4 and 6.7 in region 5, a COP of 3.3 W/W, 115 V operation and a 5-year compressor warranty — half the AURA’s. In a mild climate, on a budget, with a 115 V supply, that is a defensible buy. In a cold one it is not.

What’s wrong with it

Its published minimum heating temperature is the temperature at which every other unit here is still being measured — so in a cold climate you are buying a machine that stops where the comparison starts. No certified record exists, so there is no 5-degree capacity figure and no COP at 5 F to check.

Running cost

Senville does not publish a wattage for the SENL-12CD, so we cannot calculate what it costs to run. We are not going to estimate one. If Senville publishes a nameplate figure, this block will show the arithmetic.

Published specifications
Cooling capacity12,000 BTU/h
Heating capacity12,000 BTU/h (rated)
Heating capacity at 5 FNot published. No ENERGY STAR record exists for this model
COP at 5 FNot published
SEER221.2
EER210.1
HSPF28.7 (region 4) / 6.7 (region 5)
COP3.3 W/W
Minimum heating temperature-15 C. Senville's own FAQ puts that at 5 F
Cold climateNot an ENERGY STAR cold-climate model
ENERGY STARNot stated on Senville's page for this model
Power115 V, 1 phase, 60 Hz (103.5 - 126.5 V)
Indoor noise45 / 40.5 / 32.5 / 25 / 17.5 dB
Outdoor noise54 dB
Warranty5 years compressor, 5 years parts

Every figure above is from Senville SENL-12CD product page — SEER2 21.2, EER2 10.1, HSPF2 8.7/6.7, COP 3.3 W/W, 12,000 BTU heating, 115 V, -15 C minimum heating temperature, 5-year compressor and parts warranty. No ENERGY STAR certified record matches this model number. Blanks are shown as “not published” rather than filled in.

We are not linking a buy button for this one. If you want to look at it anyway, it is easy enough to find — but we would rather send you to something that fits your room.

Questions people actually ask

Frequently asked

What is the best mini split for a cold climate?

On certified figures, the Fujitsu AOUH09KTAP1: 17,000 BTU of heat at 5 F from a 9,000 BTU unit, at a coefficient of performance of 2.48, with SEER2 33.5. It is sold through contractors. The best complete kit you can buy yourself is the Senville AURA SENA-12HF at 11,500 BTU and COP 1.80 at 5 F.

Does the ENERGY STAR cold-climate label mean anything?

Less than you would hope. 15,319 of the 18,036 records in the certified mini-split dataset are marked cold climate: Yes — about 85 percent, across 223 brands. Shop on the heating capacity at 5 F and the COP at 5 F instead; both are published per model in the same dataset.

How cold can a mini split still heat?

Manufacturers publish a minimum heating temperature and the certified dataset publishes performance at 5 F. Senville states −22 F for its AURA line and −15 C (which its FAQ gives as 5 F) for the cheaper LETO line. The certified figures matter more: a unit rated at 5 F with a COP of 2.48 is a different machine from one whose published floor is 5 F.

Why do some mini splits make more heat at 5 F than at 17 F?

Because those are different certified test points submitted under different conditions rather than points on one curve. The Fujitsu is certified at 7,400 BTU at 17 F and 17,000 at 5 F. Compare each column against its peers rather than reading across a single row as a decline.

What is a good COP at 5 degrees for a mini split?

Among the units compared here the range is 1.80 to 2.89. Anything near or above 2.5 is strong; below 2.0 means you are using about 38 percent more electricity than the best unit in the same size class for the same heat. For reference, any electric resistance heater has a coefficient of performance of exactly 1.0. Turning COP into a monthly bill.

Should a cold-climate mini split be sized on cooling or heating?

Heating, in a cold climate. The heating load is usually the larger of the two and it peaks on the coldest night, whereas installers often size on the cooling load because that is the figure in front of them. This is exactly why the certified heating capacity at 5 F is the number to ask for. Sizing, properly.

Is a DIY mini-split kit a false economy in a cold climate?

Not necessarily, but every certified figure assumes a correct charge, correct sizing and an outdoor unit mounted clear of the snow line with room to drain its defrost cycle. A kit gets you the hardware; it does not get you those three things. Weigh the install quality alongside the specification, not after it. Is a mini split worth it?.

Sources

Where these numbers came from

Read next

Where to go from here

Back to Air Conditioners, or read how we pick.