The picks
The best ductless range hoods, for a kitchen you cannot duct
An interior wall, a rented apartment, a cabinet run with no exterior anywhere near the cooker: sometimes a duct is not an option. The hoods that recirculate instead are the one corner of kitchen ventilation where nobody publishes an airflow figure at all.
By Sawyer V. · Published
The short answer
For a kitchen that cannot be ducted, the Broan-NuTone GLA1303SS is the pick — the only one here that is ENERGY STAR certified, at 1.5 sones and 1.4 amps, and you add the charcoal filter. If you want it ductless out of the box with the filter included, the Broan 4130SF does that for about half the money — and publishes no airflow figure at all.
Fan & Frost earns a commission when you buy through our links, at no cost to you. It never changes a ranking, and we say so when the right answer is the cheaper unit or nothing at all. Full disclosure · How we pick.

At a glance
The picks, ranked
Tap any row to jump to the full reasoning. Prices are live from Amazon where we have them, and read “check price” where we don’t — never a number we cannot verify today.
| # | Product | Best for | Price |
|---|---|---|---|
| 1 | ![]() Best overall, and the only certified one Broan-NuTone GLA1303SS 30" Under-Cabinet Range Hood ENERGY STAR certified at 150 CFM and 4.6 CFM per watt, at 1.5 sones on 1.4 amps. Convertible, so it recirculates now through a charcoal filter and ducts later without replacing the hood. | A 30-inch cabinet run where you want the option of ducting later, and want a hood whose figures somebody has verified — a rental you may own one day, or a kitchen awaiting a remodel | |
| 2 | ![]() Best ductless out of the box Broan-NuTone 4130SF 30" Ductless Under-Cabinet Range Hood Ductless only, with the charcoal filter in the box, in a fingerprint-resistant stainless finish, at 3.5 sones and 2 amps. About half the price of the certified convertible. | A rented kitchen or an interior wall where ducting will never happen, and the hood needs to work the day it is screwed under the cabinet | |
| 3 | ![]() Cheapest way to get a filter over the cooker Broan-NuTone 413023 30" Ductless Range Hood The same ductless design as the 4130SF with the same included charcoal filter, in black, for less money. Broan describes it as a non-vented design for use without air ducts. | A rental, a basement kitchenette, a holiday let or any kitchen where the budget is the constraint and the alternative is no hood at all | |
| 4 | ![]() Best for a custom hood or a cabinet Broan PM300SS 21" Custom Range Hood Power Pack A 21-inch power-pack insert that goes up inside a cabinet or a custom surround: 300 max blower CFM, 3.0 sones, two speeds, and a dishwasher-safe aluminum mesh filter. | A kitchen with a built-in cabinet canopy or a custom hood surround, where you need the machinery rather than a visible appliance | |
| — | ![]() The one to skip Broan-NuTone BBN2303SS Power Pack Range Hood Insert 350 max blower CFM on the box; 100 CFM at 0.25 in w.g. in the federal dataset. The widest gap between marketing figure and certified figure we have found in this category. | Nobody shopping for a ductless kitchen — it is the most expensive hood here and its certified airflow is the lowest of any certified hood on this site |
Every piece of advice about kitchen ventilation starts the same way: duct it outside. That advice is correct and it is frequently useless. An apartment, an interior wall, a cooker on an island with a slab under it, a landlord who will not have a hole cut — the duct is not available, and the choice is a recirculating hood or nothing.
This is also the one corner of this site where the federal dataset has nothing to offer, and the reason is structural.
The finding
All 92 certified range hoods are certified ducted
We read every range-hood record in the ENERGY STAR Certified Ventilating Fans dataset: 92 of them, from Air King, Best, Broan, BSH, Elica, GE, Whirlpool and Zephyr. Every single record carries a duct size — 3.25 x 10 inches, 6 inches, 7 inches, 8 inches, 10 inches — because the test measures airflow at 0.25 inches of water gauge through a duct.
There is no recirculating test, so there is no certified recirculating figure, for any hood, from any brand. A hood running ductless has no verifiable airflow number anywhere, and the two ductless-only hoods on this page are at least consistent about that: Broan publishes no CFM for either of them.
The convertible hoods are where it gets interesting, because they publish several figures at once:
| Hood | On the box | Spec table | Certified | Sones | Filter included |
|---|---|---|---|---|---|
| Broan GLA1303SS | 350 CFM | 250 CFM | 150 CFM | 1.5 | No |
| Broan BBN2303SS | 350 CFM | — | 100 CFM | 1.0 | No |
| Broan PM300SS | 300 CFM | 300 CFM | Not certified | 3.0 | Mesh only |
| Broan 4130SF | Not published | Not published | Not certified | 3.5 | Yes, charcoal |
| Broan 413023 | Not published | Not published | Not certified | 3.5 | Yes, charcoal |
“On the box” is the max blower CFM in the product title. “Spec table” is the CFM row on Broan’s own product page. “Certified” is airflow at 0.25 in w.g. from the ENERGY STAR Certified Ventilating Fans dataset. All three describe ducted operation; none of them describes ductless.
Read the GLA1303SS row across: 350, then 250, then 150. Three numbers, all from Broan, for one hood, differing by a factor of more than two. The 350 is free air with nothing attached. The 150 is what a federal test measures once there is a duct in the way. Neither is what it does recirculating.
The trade
Numbers or a filter. You get one.
The pattern in that table is the useful thing on this page, and it is worth stating as a rule:
- The hoods that can be ducted publish figures and do not include the charcoal filter. GLA1303SS, BBN2303SS and PM300SS are all “ductless recirculation capable” with “ductless filter or kit included: No”.
- The hoods that can only recirculate include the filter and publish no figures. The 4130SF and 413023 come ready to run and carry no CFM row at all.
Which way to jump depends on one question: is the duct ever going to exist? If you might duct it in a future remodel, buy the convertible and the filter. If you never will, the ductless-only hood is cheaper, is complete in the box, and you were not going to get a verified airflow figure either way.
This one is not a DIY job
A recirculating hood does nothing for the moisture a kitchen makes, and over the holidays a kitchen makes a lot of it. Boiling, roasting and washing up all put water into the air, and a charcoal filter does not remove water — it returns it to the room, where it condenses on the coldest glass in the house. Why that produces streaming windows, and what does fix it, and the meter that tells you whether it is a problem.
Install
Three measurements, in this order
- Cabinet width. 30 inches is the volume size and everything on this page except the inserts is 30 inches. The PM300SS insert is 21.375 inches and needs a surround.
- Height above the cooktop. Broan publishes an 18-inch minimum for the GLA1303SS and the 4130SF. Lower than that is a warranty and fire question, not a preference.
- Depth, against your cabinet. 17.5 inches for the ductless hoods, 19.68 for the certified convertible. A hood deeper than the cabinet above it looks like a mistake and catches sleeves.
And one electrical note: these are small loads — 1.4 to 2 amps at 120 V — so unlike a bathroom fan with a heater in it, a range hood is not a circuit problem.
Say the unwelcome thing
Do not buy a ductless hood for a gas range and expect it to ventilate.
A charcoal filter captures grease and some odor. It does not exhaust anything, which means the products of combustion from a gas burner stay in the room. That is a different problem from a smell, and no recirculating hood on the market solves it.
If the cooker is gas and ducting is genuinely impossible, the honest mitigations are a window that opens, a continuously running extractor elsewhere in the dwelling, and a monitor so you know what the air is actually doing. Air quality monitors, on published sensor accuracy.
In full
Every pick, and what is wrong with it
Published specifications only, each linked to the page it came from. Where a manufacturer publishes nothing, the row says so — we do not fill blanks in.

1. Best overall, and the only certified one
Broan-NuTone GLA1303SS 30" Under-Cabinet Range Hood
Broan-NuTone · model GLA1303SS
ENERGY STAR certified at 150 CFM and 4.6 CFM per watt, at 1.5 sones on 1.4 amps. Convertible, so it recirculates now through a charcoal filter and ducts later without replacing the hood.
150 CFM at 0.25 in w.g. and 4.6 CFM per watt, both ENERGY STAR certified, at 1.5 sones and 1.4 amps at 120 V, through a 7-inch duct when it is ducted. The hood is 30 inches wide, 19.68 deep and 5.98 high, with an 18-inch minimum height above the cooktop.
It is the only hood on this page with a federal number attached, and on a page about ductless hoods that deserves a caveat: the certification measures it ducted. Nobody certifies recirculating performance (see below). What the certification buys you is confidence about the blower and the 1.5-sone rating, both of which carry over.
Broan’s spec table says “Ductless Filter Or Kit Included: No”. Budget for the charcoal filter. It is the cheapest line item in this project and the one people discover after the hood is on the wall.
1 year, 3 years on the LED, with a 5-watt bulb included. Both of those are better than the ductless-only hoods below, which ship with no bulbs at all.
What’s wrong with it
The charcoal filter kit is not included, so the ductless mode is an extra purchase. And Broan publishes three different airflow numbers for this hood — 350 on the box, 250 in the spec table, 150 certified — none of which describes it running ductless.
Running cost
Broan-NuTone does not publish a wattage for the GLA1303SS, so we cannot calculate what it costs to run. We are not going to estimate one. If Broan-NuTone publishes a nameplate figure, this block will show the arithmetic.
| Air delivery, certified | 150 CFM at 0.25 in w.g. (ENERGY STAR Certified Ventilating Fans dataset) |
|---|---|
| Efficacy, certified | 4.6 CFM per watt |
| Air delivery, Broan's spec table | 250 CFM |
| Air delivery, on the box | 350 max blower CFM |
| Noise | 1.5 sones |
| Duct size | 7 in |
| Rated amps | 1.4 A at 120 V |
| Ductless capable | Yes, but the charcoal filter kit is NOT included |
| Light | 5 W bulb, included |
| Minimum height above cooktop | 18 in |
| Dimensions | 30 W x 19.68 D x 5.98 H in |
| ENERGY STAR | Certified |
| Warranty | 1 year, 3 year LED |
Every figure above is from Broan-NuTone GLA1303SS product page — ENERGY STAR certified, 1.5 sones, 250 CFM in the spec table against 350 max blower CFM in the title, 7 in duct, 1.4 rated amps, ductless capable with the filter kit sold separately. Certified airflow and efficacy from the ENERGY STAR Certified Ventilating Fans dataset. Blanks are shown as “not published” rather than filled in.

2. Best ductless out of the box
Broan-NuTone 4130SF 30" Ductless Under-Cabinet Range Hood
Broan-NuTone · model 4130SF
Ductless only, with the charcoal filter in the box, in a fingerprint-resistant stainless finish, at 3.5 sones and 2 amps. About half the price of the certified convertible.
Charcoal filter included, 30 inches wide, 3.5 sones, 2 amps at 120 V, 18-inch minimum height above the cooktop, one-year warranty, and a PrintGuard stainless finish that is the practical reason to pay more for this than for the black 413023 below.
There is no airflow figure on Broan’s page for this hood. Its specification table lists filter type, sones, amps and dimensions, and the CFM row that every other Broan hood page carries is simply absent. We are not going to put a number there.
That absence is not Broan being evasive; it is what happens when a product has no test to point at. A recirculating hood’s output depends on the filter’s loading, and that changes from the day you fit it.
3.5 sones is the honest cost of the category. The certified convertible manages 1.5. Over a gas hob at dinner time, that difference is the difference between a hood you run and a hood you switch on when the smoke alarm threatens. The certified hoods, ranked on efficacy.
What’s wrong with it
Broan publishes no CFM figure for it at all — not a free-air number, not a certified one, nothing. At 3.5 sones it is also more than twice as loud as the certified hood, and it ships with no light bulbs.
Running cost
Broan-NuTone does not publish a wattage for the 4130SF, so we cannot calculate what it costs to run. We are not going to estimate one. If Broan-NuTone publishes a nameplate figure, this block will show the arithmetic.
| Air delivery | Not published. Broan publishes no CFM figure for this hood at all |
|---|---|
| Noise | 3.5 sones |
| Filter | Charcoal, INCLUDED |
| Ductless recirculation | Yes — this hood is ductless only |
| Rated amps | 2 A at 120 V |
| Minimum height above cooktop | 18 in |
| Dimensions | 30 W x 17.5 D x 6 H in |
| Light bulbs included | No |
| ENERGY STAR | Not certified |
| Warranty | 1 year |
Every figure above is from Broan-NuTone 4130SF product page — ductless recirculation capable with the charcoal filter included, 3.5 sones, 2 rated amps, 30 x 17.5 x 6 in, 1-year warranty, not ENERGY STAR certified, no airflow figure published. Blanks are shown as “not published” rather than filled in.

3. Cheapest way to get a filter over the cooker
Broan-NuTone 413023 30" Ductless Range Hood
Broan-NuTone · model 413023
The same ductless design as the 4130SF with the same included charcoal filter, in black, for less money. Broan describes it as a non-vented design for use without air ducts.
Broan’s own description is “non-vented design for use without air ducts”, which is the clearest statement of what you are buying anywhere on this page. Charcoal filter in the box, 3.5 sones, 2 amps, 30 x 17.5 x 6 inches.
It is the hood for the situation where the realistic alternative is a window. A recirculating hood captures grease and some odor on a charcoal medium and returns the air to the room; it does not remove moisture, and it does not remove combustion products from a gas burner. Over a gas hob, that second point is the one to take seriously. What cooling and ventilation do and do not do for indoor air.
No light bulbs included, and Broan publishes no bulb wattage or socket type on the page, so check before you buy lamps.
Same caveat as its stainless sibling and worth repeating: no CFM figure is published for this hood.
What’s wrong with it
Same missing airflow figure, same 3.5 sones, same 2 amps, no bulbs included, one-year warranty — and black steel shows grease in a way that fingerprint-resistant stainless does not.
Running cost
Broan-NuTone does not publish a wattage for the 413023, so we cannot calculate what it costs to run. We are not going to estimate one. If Broan-NuTone publishes a nameplate figure, this block will show the arithmetic.
| Air delivery | Not published. Broan publishes no CFM figure for this hood at all |
|---|---|
| Noise | 3.5 sones |
| Filter | Charcoal, INCLUDED |
| Ductless recirculation | Yes. Broan describes it as a non-vented design for use without air ducts |
| Rated amps | 2 A at 120 V |
| Dimensions | 30 W x 17.5 D x 6 H in |
| Light bulbs included | No |
| ENERGY STAR | Not certified |
| Warranty | 1 year |
Every figure above is from Broan-NuTone 413023 product page — non-vented design for use without air ducts, charcoal filter included, 3.5 sones, 2 rated amps, 1-year warranty, no airflow figure published. Blanks are shown as “not published” rather than filled in.

4. Best for a custom hood or a cabinet
Broan PM300SS 21" Custom Range Hood Power Pack
Broan · model PM300SS
A 21-inch power-pack insert that goes up inside a cabinet or a custom surround: 300 max blower CFM, 3.0 sones, two speeds, and a dishwasher-safe aluminum mesh filter.
300 max blower CFM, 3.0 sones, two speeds, 120 V, in a chassis 21.375 inches wide and 2.8 inches high that disappears into a cabinet bottom. Broan sells matching stainless liners for it if there is no cabinet.
This is the one the kitchen fitters buy, because it solves the aesthetic problem: in a kitchen where a visible hood is wrong, the insert goes up inside joinery and all you see is a filter and two lights.
Dishwasher-safe aluminum mesh with quick-release filters is a real running-cost advantage over charcoal. A mesh grease filter is washed; a charcoal filter is bought.
For ductless use you will still need the charcoal element, and Broan lists it as not included. “300 max blower CFM” is a free-air figure measured with nothing in the way — see the table below for what happens to such figures under test.
What’s wrong with it
Ductless recirculation is listed as capable but no charcoal filter or kit is included, the 300 CFM is a free-air blower figure rather than a certified one, and it is not ENERGY STAR certified. It also needs the cabinet or liner to exist already.
Running cost
Broan does not publish a wattage for the PM300SS, so we cannot calculate what it costs to run. We are not going to estimate one. If Broan publishes a nameplate figure, this block will show the arithmetic.
| Air delivery | 300 max blower CFM |
|---|---|
| Noise | 3.0 sones |
| Filter | Dishwasher-safe aluminum mesh |
| Ductless recirculation | Yes, but no charcoal filter or ductless kit is included |
| Speeds | 2 |
| Dimensions | 21.375 W x 11.4375 D x 2.8125 H in |
| Power | 120 V |
| Light bulbs included | Yes |
| ENERGY STAR | Not certified |
| Warranty | 1 year |
Every figure above is from Broan PM300SS product page — 300 max blower CFM, 3.0 sones, aluminum mesh filter, ductless recirculation capable with no kit included, 2 speeds, 1-year warranty. Blanks are shown as “not published” rather than filled in.

Skip this one
Broan-NuTone BBN2303SS Power Pack Range Hood Insert
Broan · model BBN2303SS
350 max blower CFM on the box; 100 CFM at 0.25 in w.g. in the federal dataset. The widest gap between marketing figure and certified figure we have found in this category.
Let us be fair to it first. 1.0 sones is the quietest rating on this page, it is ENERGY STAR certified, and as a built-in insert it solves the same joinery problem the PM300SS does with a nicer light.
Then the numbers. Broan markets it as 350 max blower CFM. ENERGY STAR certifies it at 100 CFM at 0.25 in w.g., with an efficacy of 3.0 CFM per watt. That is the lowest certified airflow of any range hood this site ranks, behind a 30-inch hood costing a quarter as much.
And it is being asked to recirculate through a 3.25 x 10-inch rectangular duct opening, which is the smallest cross-section in the comparison. In ductless mode the air has to come back out through the filter at the front, against the cabinet above.
If you want a certified insert, this is a reasonable thing to own in a ducted kitchen. On a page about kitchens that cannot be ducted it is the wrong end of every trade-off. Where it sits among the certified field.
What’s wrong with it
A 250 CFM gap between the number on the box and the number under test, at the highest price on this page, and with no ductless kit included either. The 1.0-sone rating is genuinely excellent and it is not enough to rescue the rest.
Running cost
Broan does not publish a wattage for the BBN2303SS, so we cannot calculate what it costs to run. We are not going to estimate one. If Broan publishes a nameplate figure, this block will show the arithmetic.
| Air delivery | 100 CFM at 0.25 in w.g. |
|---|---|
| Efficacy | 3.0 CFM per watt |
| Noise | 1.0 sones |
| Duct size | 3.25 x 10 in rectangular |
| Lighting | LED, 308 lumens; not an ENERGY STAR lamp |
| Marketing claim | 350 max blower CFM |
| Unit type | Range hood insert, 30 in |
| ENERGY STAR | Certified |
Every figure above is from ENERGY STAR Certified Ventilating Fans dataset. Blanks are shown as “not published” rather than filled in.
We are not linking a buy button for this one. If you want to look at it anyway, it is easy enough to find — but we would rather send you to something that fits your room.
Questions people actually ask
Frequently asked
What is the best ductless range hood?
The Broan-NuTone GLA1303SS, because it is the only one that anybody has certified: ENERGY STAR at 150 CFM and 4.6 CFM per watt, 1.5 sones, 1.4 amps. It is convertible, so it recirculates through a charcoal filter you buy separately and can be ducted later. If you want it ductless with the filter in the box, the Broan 4130SF does that for about half the money.
Do ductless range hoods actually work?
They capture grease and some odor on a charcoal filter and return the air to the room. They do not remove moisture, and they do not exhaust the products of combustion from a gas burner. Within that limit they are useful; outside it, no recirculating hood on the market can help.
How much air does a ductless range hood move?
Nobody publishes a figure, and the reason is structural: all 92 range hoods in the ENERGY STAR certified dataset are certified ducted, at 0.25 inches of water gauge through a stated duct size. There is no recirculating test, so there is no certified recirculating number for any hood from any brand. The certified hoods and their real figures.
Why does one range hood have three different CFM numbers?
Because they measure different things. Broan's GLA1303SS is titled 350 max blower CFM, its own spec table says 250 CFM, and ENERGY STAR certifies it at 150 CFM at 0.25 in w.g. The first is free air with nothing attached, the last is a federal test with a duct in the way. Only the last is comparable between brands.
Is a charcoal filter included with a ductless range hood?
It depends which kind you buy, and the pattern is consistent. Broan's ductless-only hoods (4130SF, 413023) include the charcoal filter and publish no airflow figure. Its convertible and insert hoods (GLA1303SS, BBN2303SS, PM300SS) publish figures and list 'ductless filter or kit included: No'.
How high above the cooktop should a range hood go?
Broan publishes an 18-inch minimum height above the cooktop for the GLA1303SS and the 4130SF, and that is a specification rather than a suggestion. Going lower is a warranty question and a fire question; going much higher loses capture, which a recirculating hood can least afford.
Does a ductless range hood help with condensation?
No — it makes the moisture situation worse than ducting, because everything a kitchen boils off stays in the house. If the windows stream when you cook, the answer is extraction somewhere in the dwelling, not a charcoal filter over the hob. What actually stops condensation.
Sources
Where these numbers came from
- ENERGY STAR Certified Ventilating Fans dataset — all 92 certified range hood records, every one of which carries a duct size, with certified airflow at 0.25 in w.g. and efficacy in CFM per watt
- Broan-NuTone GLA1303SS product page — ENERGY STAR certified, 1.5 sones, 250 CFM in the spec table against 350 max blower CFM in the title, 7 in duct, 1.4 rated amps, 18 in minimum height, ductless capable with the filter kit not included, 1 year / 3 year LED warranty
- Broan-NuTone 4130SF product page — ductless recirculation capable with the charcoal filter included, 3.5 sones, 2 rated amps, 30 x 17.5 x 6 in, 18 in minimum height, no airflow figure published
- Broan-NuTone 413023 product page — non-vented design for use without air ducts, charcoal filter included, 3.5 sones, 2 rated amps, no airflow figure published
- Broan PM300SS product page — 300 max blower CFM, 3.0 sones, dishwasher-safe aluminum mesh filter, ductless recirculation capable with no kit included, 2 speeds, 21.375 in wide
- Broan-NuTone BBN2303SS product page — 350 max blower CFM, 1 sone, ENERGY STAR certified, ductless recirculation capable with no kit included
Read next
Where to go from here
Back to Whole-House Airflow, or read how we pick.